A SERVICE OF

logo

INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A
(Revision Date: Feb. 25, 2008)
8. RFID Module: B-SA704-RFID-U2-EU-R
8- 16
AGC Threshold Setting
The B-SA704-RFID-U2-EU-R chooses a tag to write data on according to a radio intensity of RFID tags (AGC
value).
An AGC threshold value has been set to 11 (0Bh) as factory default, but it may be necessary to change this value
according to the tag type to be used.
When the factory default threshold value is not proper for the tag type used, follow the procedure below to
configure the following settings.
As the changes are stored in the internal memory, they are retained after the printer power is turned off and on
again. When the tag type is changed or data write cannot be operated properly, perform the setting again.
Step 1. Load an RFID tag embedded media in the printer.
Step 2. Follow the procedure below to measure the radio intensity of the tags.
1) Place the media so that an RFID tag (IC chip) is positioned above the Antenna, and close the Top
Cover.
Note: If an RFID tag is not positioned above the Antenna while the Print Head is at a print start position,
use @003 command to adjust the media position so that an RFID tag is positioned above the
Antenna. For detail of the command, refer to the External Equipment Interface Specification
(Printer Command Manual).
2 Start the printer in the system mode and perform a read test to measure the AGC value.
Media
RFID
Tag
Print Head
Platen
Antenna
Antenna Cable
RFID Module
Printe
r
When “<10>RFID” is displayed, press the [PAUSE] key.
Read test menu is displayed.
Press the [FEED] or [RESTAT] key to choose “READ TEST ON”.
Press the [PAUSE] key to implement a read test.
[RESTART]
<10>RFID
<10>RFID
READ TEST ON
<1>DIAG. V1.6
[PAUSE]
[FEED] or [RESTAT]
[PAUSE]
Turn the printer on while holding down the
[FEED] and [PAUSE] keys at the same time.
When “<1>DIAG. V1.6” is displayed, press the [RESTART] key.
Example
Continued to the next page
<10>RFID
READING•••.
<10>RFID
READ TEST OFF