Aga Ranges DESN 512387 A Double Oven User Manual


 
The pressure test point is situated at the rear right hand side of the hotplate.
Place the wok burner head, burner cap and ring into position on the hotplate. Light the burner by
pushing in the appropriate control knob, and turning it anti-clockwise IGNITION position, until gas
ignites, then continue to turn to the FULL ON position.
For LPG appliance (propane), the pressure should be 37mbar (14.8 inches water gauge).
Turn off the tap, disconnect the pressure gauge and refit test point blanking screw.
11
PRESSURE TESTING
POSITION OF GAS BAYONET ON WALL (locate in shaded areas)
IMPORTANT: THE GAS SUPPLY CONNECTION AT THE WALL MUST NOT PROJECT
OUT FROM THE WALL BY MORE THAN 45MM, SO THAT IT DOES NOT FOUL WITH THE
BACK OF THE COOKER.
Fig. 4 DESN 512390 A