Aga Ranges DESN 512387 A Double Oven User Manual


 
56
Fig. 31
DESN 513532
DESN 513530Fig. 30
K. TO REMOVE THERMOCOUPLE (LHF BURNER)
1. Isolate from electric supply.
2. Proceed as ‘TO REMOVE HOTPLATE’.
3. Undo the nut fixing the thermocouple in place.
4. Push the thermocouple down and pull out from under the burner.
5. Disconnect the other end of the thermocouple cable from the gas valve. This is a push on
jack connector.
6. Re-assemble in reverse order.