Alto-Shaam 10.10ESG Oven User Manual


 
An electrical wiring diagram is located behind the control
panel on the left side of the oven. This appliance must be
branch circuit protected with proper ampacities, in
accordance with the wiring diagram located in the
electrical compartment of the oven.
Wire size for the main incoming power to the unit must
match the minimum size listed in the specifications
applicable to the specific oven model. For supply
connections, locate the wire size posted on the label
located on the electrical control box cover, behind the
service panel.
Before operating the oven, check all cable connections in
the electrical connection area for tightness since
connections can loosen during transport.
NOTE: After both water and elecrical connections have
been completed, operate the oven in any cooking
mode for a period of 15 minutes and recheck the
main power connections at the terminal block to
make certain they remain tight.
GAS COMBITHERM INSTALLATION MANUAL #MN-28676
PG. 14
®
COMBITHERM
ELECTRICAL & INSTALLATION REQUIREMENTS
AVERTISSEMENT: Directives pour la prise
de courant électrique Cet appareil est muni
d'une fiche à trios branches (prise de
Courant) afin de vous proéger des chocs et
doit être branché Directemet dans un
receptacle adequate de prise do courant À
trios branches. II ne faut pas couper ou
enlever une banche De cette fiche.
M
ODEL VOLTAGE PHASE CYCLE
/H
Z AMPS KW CIRCUIT AWG
6•10esG 110-120 1 50/60 5.7 .68 20 A 2 WIRE
PLUS GROUND
6
•10esG/
SK 1
10-120 1 50/60 9.5 1.14 20 A
AWG 1
2
7•14esG 110-120 1 50/60 5.7 .68 20 A 2
WIRE
PLUS GROUND
7•14esG/SK 110-120 1 50/60 9.5 1.14 20 A AWG 12
10•10esG 110-120 1 50/60 5.7 .68 20 A 2
WIRE
PLUS GROUND
10•10esG/SK 110-120 1 50/60 9.5 1.14 20 A AWG 12
10•20esG 110-120 1 50/60 7.8 .936 20 A 2
WIRE
PLUS GROUND
AWG 12
12•18esG 110-120 1 50/60 7.8 .936 20 A 2
WIRE
PLUS GROUND
AWG 12
20•20esG 110-120 1 50/60 22.0 2.64 30 A 2
WIRE
PLUS GROUND
AWG 10
O
THER VOLTAGES AVAILABLE
: Range 200 — 415V, 1 or 3 ph, 50 or 60 Hz
380-415V:
To prevent an electrical shock hazard
between the appliance and other appliances
or metal parts in close vicinity, an
equalization-bonding stud is provided.
An equalization bonding lead must be
connected to this stud and the other
appliances / metal parts to provide
sufficient protection against potential
difference. The terminal is marked with
the following symbol.
D A N G E R
ELECTRICAL GROUNDING
INSTRUCTIONS:
This appliance is equipped with a
three-pronged (grounding) plug for
your protection against shock hazard
and should be plugged directly into a
properly grounded three-prong
receptacle. Do not cut or remove the
grounding prong from this plug.