GAS COMBITHERM — INSTALLATION MANUAL #MN-28676
PG.4
®
COMBITHERM
6•10ESG SPECIFICATIONS
CAPACITY
FULL-SIZE PANS: 20" x 12" x 2-1/2" Six (6) Four (4)
GN 1/1: 530 x 325 x 65mm Six (6) Four (4)
HALF-SIZE SHEET PANS:* 18" x 13" x 1" Six (6) Five (5)
ON WIRE SHELVES ONLY
72 lb (33 kg) MAXIMUM
VOLUME MAXIMUM
: 45 QUARTS (57 LITERS)
CLEARANCE REQUIREMENTS
LEFT: 6" (152mm) PLUS SERVICE ACCESS: 18" (457mm) RECOMMENDED
20" (508mm) FROM HEAT PRODUCING EQUIPMENT
RIGHT
: 4" (102mm) TOP: 20" (508mm) FOR AIR MOVEMENT
BACK
: 4" (102mm) BOTTOM: 5-1/8" (130mm) FOR LEGS
COUNTER
-TOP INSTALLATIONS MUST MAINTAIN 4" (102mm)
MINIMUM CLEARANCE FROM THE COUNTER SURFACE.
GAS REQUIREMENTS
CONNECTED ENERGY LOAD: 45,000 Btu/hr
HOOK-UP: 3/4" NPT
MINIMUM CONNECTED PRESSURE: 5.5" W.C. (Natural Gas)
9" W.C. (Propane)
MAXIMUM CONNECTED PRESSURE: 14" W.C.
G
AS TYPE MUST BE SPECIFIED ON ORDER
.
WEIGHT
NET 377 lb EST. (171 kg) EST.
SHIP 442 lb EST. (200 kg) EST.
CRATE 40" X 45" X 40" EST.
DIMENSIONS: (1016 x 1143 x 1016mm)
ELECTRICAL 6•10ESG 6•10ESG/sk
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW AMPS kW
110 - 120 1 50/60 2 Wire plus ground, AWG 12 5.7 0.68 9.5 1.14
OTHER VOLTAGES AVAILABLE: Range 200 — 415V — 1 or 3 ph, 50 or 60 Hz
WATER REQUIREMENTS
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
INSTALLATION REQUIREMENTS
Oven must be installed level. Hood installation. Water supply
shut-off valve and back-flow preventer. Alternate burner orifice
is required for installation sites at elevations of 3,000 feet (914m)
above sea level.
5
-1/2" (140mm)
Steam
V
ent
(Top)
Untreated Water Intake (Bottom)
Treated Water Intake (Bottom)
Electrical
Connection (Bottom)
Gas Connection
(
Bottom)
2" (50mm)
47-5/16" (1201mm)
42-1/16" (1068mm)
40-1/8"
(
1018mm)
37" (939mm)
34-5/16"
(871mm)
Water Drain
(Bottom)
21-11/16"
(550mm)
5-1/2"
(140mm)
25"
(635mm)
7-1/2"
(191mm)
58-3/16" (1478mm)
6-1/4" (159mm)
5" (125mm)
3-1/16"
(76mm)
27-3/4"
(704mm)
34" (863mm)
2-3/8" (60mm)
10-5/8
"
(270mm)
19-3/8"
(492mm)
11-1/2" (292mm)
3
-5/8"
(92mm)
1
5-5/8"
(396mm)
Water Drain
(Side Back)
DIMENSIONS: H x W x D
EXTERIOR:
34" x 42-1/16" x 37" (863mm x 1068mm x 939mm)
EXTERIOR WITH RETRACTABLE DOOR:
34" x 46-1/16" x 37" (863mm x 1170mm x 939mm)
INTERIOR:
17-3/4" x 17-3/8" x 26-13/16" (450mm x 440mm x 680mm)
WATER QUALITY MINIMUM STANDARDS
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure
that incoming water supply is compliant with the specifications
listed through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant Inlet Water Requirements
(untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm