Alto-Shaam 10.10ESG Oven User Manual


 
GAS COMBITHERM INSTALLATION MANUAL #MN-28676
PG.5
®
COMBITHERM
10•10ESG SPECIFICATIONS
CAPACITY
FULL-SIZE PANS: 20" x 12" x 2-1/2" Ten (10) Eight (8)
GN 1/1: 530 x 325 x 65mm Ten (10) Eight (8)
HALF-SIZE SHEET PANS:* 18" x 13" x 1" Ten (10) Nine (9)
ON WIRE SHELVES ONLY
120 lb (54 kg) MAXIMUM
VOLUME MAXIMUM
: 75 QUARTS (95 LITERS)
WEIGHT
NET 490 lb EST. (222 kg) EST.
SHIP 530 lb EST. (240 kg) EST.
CRATE 50" X 45" X 40" EST.
DIMENSIONS: (1270 x 1143 x 1016mm)
ELECTRICAL 10•10ESG 10•10ESG/sk
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW AMPS kW
110 - 120 1 50/60 2 Wire plus ground, AWG 12 5.7 .68 9.5 1.14
OTHER VOLTAGES AVAILABLE: Range 200 — 415V — 1 or 3 ph, 50 or 60 Hz
21-11/16"
(550mm)
5-1/2"
(140mm)
42-1/16" (1068mm)
40-1/8"
(1018mm)
37" (939mm)
34-5/16"
(
871mm)
W
ater Drain
(Bottom)
5" (125mm)
3-1/16"
(76mm)
37-3/8" (949mm)
43-5/8" (1108mm)
S
team
Vent
(Top)
Untreated Water
Intake (Bottom)
E
lectrical
Connection (Bottom)
Gas Connection
(
Bottom)
2" (50mm)
47-5/16" (1201mm)
58-3/16" (1478mm)
2-3/8" (60mm)
10-5/8
"
(270mm)
19-3/8"
(492mm)
15-5/8"
(396mm)
Water Drain
(Side Back)
25"
(635mm)
7-1/2"
(191mm)
6-1/4" (159mm)
5-1/2" (140mm)
Treated Water Intake (Bottom)
11-1/2" (292mm)
3
-5/8"
(92mm)
DIMENSIONS: H x W x D
EXTERIOR:
43-5/8" x 42-1/16" x 37" (1108mm x 1068mm x 939mm)
EXTERIOR WITH RETRACTABLE DOOR:
43-5/8" x 46-1/16" x 37" (1108mm x 1170mm x 939mm)
INTERIOR:
27-3/8" x 17-3/8" x 26-13/16" (695mm x 440mm x 680mm)
*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
CLEARANCE REQUIREMENTS
LEFT: 6" (152mm) PLUS SERVICE ACCESS: 18" (457mm) RECOMMENDED
20" (508mm) F
ROM HEAT PRODUCING EQUIPMENT
RIGHT: 4" (102mm) TOP: 20" (508mm) FOR AIR MOVEMENT
BACK
: 4" (102mm) BOTTOM: 5-1/8" (130mm) FOR LEGS
COUNTER
-TOP INSTALLATIONS MUST MAINTAIN 4" (102mm)
MINIMUM CLEARANCE FROM THE COUNTER SURFACE.
GAS REQUIREMENTS
CONNECTED ENERGY LOAD: 68,000 Btu/hr
HOOK-UP: 3/4" NPT
MINIMUM CONNECTED PRESSURE: 5.5" W.C. (Natural Gas)
9" W.C. (Propane)
MAXIMUM CONNECTED PRESSURE: 14" W.C.
GAS TYPE MUST BE SPECIFIED ON ORDER.
WATER REQUIREMENTS
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
INSTALLATION REQUIREMENTS
Oven must be installed level. Hood installation. Water supply
shut-off valve and back-flow preventer. Alternate burner orifice
is required for installation sites at elevations of 3,000 feet (914m)
above sea level.
WATER QUALITY MINIMUM STANDARDS
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure
that incoming water supply is compliant with the specifications
listed through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant Inlet Water Requirements
(untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm