Alto-Shaam 10.18 Oven User Manual


 
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28897
PG. 13
10•18ESi SPECIFICATIONS
®
COMBITHERM
CA PA CI TY
FULL-SIZE PANS: 20" x 12" x 2-1/2" Twenty (20) Eighteen (18)
GN 1/1: 530 x 325 x 65mm Twenty (20) Eighteen (18)
GN 2/1: 650 x 530 x 65mm Ten (10) Eight (8)
FULL-SIZE SHEET PANS:* 18" x 26" x 1" Ten (10) Nine (9)
ON WIRE SHELVES ONLY
240 lb (109 kg) MAXIMUM
VOLUME MAXIMUM
: 150 QUARTS (190 LITERS)
WE IGH T
NET 520 lb (236 kg)
SHIP 640 lb (290 kg)
CRATE 46" X 51" X 46" EST.
DIMENSIONS: (1168 x 1295 x 1168mm)
EL EC TR IC AL 10 •1 8E Si 10 •1 8E Si /sk
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW AMPS kW
at 208 3 50/60 3 Wire plus ground 61.1/ph 22.0 62.5/ph 22.5
at 240 AWG 2 70.3/ph 29.2 71.5/ph 29.7
at 380 3 50/60 4 Wire plus ground 33.5/ph 22.0 34.2/ph 22.5
at 415 AWG 8 40.7/ph 29.2 41.4/ph 29.7
at 440 3* 50/60 3 Wire plus ground 35.7/ph 27.2 36.4/ph 27.7
at 480 AWG 8 43.5/ph 36.1 44.0/ph 36.6
* ELECTRICAL SERVICE CHARGE APPLIES
208-240
380-415
440-480
30"
(760mm)
4-11/16" (120mm)
2-5/16" (58mm)
22-3/8"
(568mm)
15-1/2"
(393mm)
12-3/4"
(323mm)
Electrical Connection
(
Bottom)
2" (50mm)
46-7/8" (1190mm)
4
3-7/8"
(1114mm)
41-15/16"
(1064mm)
40-1/8"
(
1019mm)
25-5/8"
(650mm)
8-11/16"
(219mm)
6-1/4" (158mm)
Water Drain
(
Bottom)
42-13/16"
(1087mm)
33-1/8"
(840mm)
4-15/16"
(125mm)
Steam
Vents
(Top)
Water Drain
(Side Back)
69-3/8" (1761mm)
7-9/16" (192mm)
40-7/16" (1026mm)
32-7/8"
(834mm)
Treated Water
I
ntake (Bottom)
Untreated Water
Intake (Bottom)
L
ow Pressure
Valve (Top)
DI ME NS IO NS: H x W x D
EXTERIOR:
40-7/16" x 43-7/8" x 42-13/16" (1026mm x 1114mm x 1087mm)
EXTERIOR WITH RETRACTABLE DOOR:
40-7/16" x 47-7/8" x 42-13/16" (1026mm x 1216mm x 1087mm)
INTERIOR:
30-3/4" x 23-1/2" x 28-7/16" (781mm x 596mm x 722mm)
*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
IN STA LL ATI ON R EQ UI RE MEN TS
Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow
preventer.
CL EA RA NC E R EQU IR EM EN TS
LEFT: 6" (152mm) PLUS SERVICE ACCESS: 18" (457mm) RECOMMENDED
20" (508mm) FROM HEAT PRODUCING EQUIPMENT
RIGHT
: 4" (102mm) TOP: 20" (508mm) FOR AIR MOVEMENT
BACK
: 4" (102mm) BOTTOM: 5-1/8" (130mm) FOR LEGS
COUNTER
-TOP INSTALLATIONS MUST MAINTAIN 4" (102mm) MINIMUM
CLEARANCE FROM COUNTER SURFACE
.
WATE R R EQ UIR EME NT S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
WATE R Q UA LIT Y M IN IM UM STA ND AR DS
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure that
incoming water supply is compliant with the specifications listed
through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant Inlet Water Requirements
(untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm