Alto-Shaam 10.18 Oven User Manual


 
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28897
PG. 21
®
COMBITHERM
INSTALLATION REQUIREMENTS
MOBILE EQUIPMENT RESTRAINT
Any appliance that is not furnished with a power
supply cord but includes a set of casters must be
installed with a tether. Adequate means must be
provided to limit the movement of this appliance
without depending on or transmitting stress to the
electrical conduit. The following requirements apply:
1. Casters must be a maximum height of 6" (152mm).
2. Two of the casters must be the locking type.
3.
Such mobile appliances or appliances on mobile
stands must be installed with the use of a flexible
connector secured to the building structure.
A mounting connector for a restraining device is
located on the lower back flange of the appliance
chassis or on an oven stand, approximately
18" (457mm) from the floor. A flexible connector is
not supplied by nor is it available from the factory.
W A R N I N G
FAILURE TO PROPERLY INSTALL THE
DRIP TRAY CAN OR WILL CAUSE
MAJOR EQUIPMENT DAMAGE AND
WILL RESULT IN A LEAKAGE
HAZARD THAT CAN CAUSE
PERSONAL INJURY.
W A R N I N G
RISK OF ELECTRIC SHOCK.
Appliance must be secured
to building structure.
DRIP TRAY INSTALLATION
The appliance is shipped without the drip tray
installed. This must be installed before equipment
operation begins.
Remove screws from bottom of oven (see illustration
shown at right).
Position drip tray assembly beneath oven. Secure with
lock washer and phillips screws supplied.
Cut drip tray hose to length and attach to drip tray
assembly. Secure with 20mm clamp. Secure other end
of drip tray hose to drain fitting connection with clamp.
ITEM
NO
.
PART
NO
.
PART DESCRIPTION
1 SCREWS
2 DRIP TRAY
3 HO-2957 DRIP TRAY HOSE
BOTTOM VIEW