Alto-Shaam 10.18 Oven User Manual


 
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28897
PG. 20
®
COMBITHERM
MOTOR WITH
ROTATION
DIRECTION
ELECTRICAL
CONNECTION
ELECTRICAL PANEL
TERMINAL BLOCK
GROUND
WA R N I N G
FOLLOWING ELECTRICAL CONNECTION,
THE FAN MUST
ROTATE IN THE SAME
DIRECTION AS THE ARROW LOCATED
ON THE OVEN FAN MOTOR.
T H I S A P P L I A N C E W I L L N O T F U N C T I O N
P R O P E R LY A N D D A M A G E C A N O C C U R I F
T H E M OT O R R O TAT I O N I S N O T C O R R E C T.
TO CHANGE MOTOR DIRECTION,
EXCHANGE TWO OF THE INCOMING PHASES.
D A N G E R
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.