Alto-Shaam 10.18 Oven User Manual


 
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28897
PG. 23
®
COMBITHERM
WATER SUPPLY & INSTALLATION REQUIREMENTS
Flush the water line at the installation site.
I
nstall water intake filters (provided) [see figure 1] before
connecting the oven to the water supply.
A hose connector is supplied for flexible hose connection
t
o the COLD
w
ater source.
PIPE SEALING TAPE (T
EFLON
®) MUST BE USED AT
ALL CONNECTION POINTS.
The use of a pipe sealing
compound is not recommended.
WATE R R EQ UIR EME NT S
T
WO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi
2.8 to 6.2 bar
* Can manifold off of one 3/4" line
REFER TO PUBLISHED SPECIFIC WATER REQUIREMENTS
WATER DRAIN: 1-1/2" C
ONNECTION WITH AIR GAP
NOTE:
BOTH TREATED AND UNTREATED WATER
CONNECTIONS MUST BE CONNECTED FOR PROPER
OPERATION OF THE OVEN. BOTH CONNECTIONS
CAN BE TREATED WATER, BUT SHOULD NEVER BE
CONNECTED TO ONLY UNTREATED WATER.
UNIONS OR FLEXIBLE LINES SHOULD BE USED TO
ALLOW FOR OVEN MOVEMENT WHEN BEING
SERVICED OR CLEANING IS NEEDED.
REFER TO DIMENSION DRAWINGS BEGINNING ON
PAGE 4 FOR PROPER INTAKE LOCATIONS.
Incoming cold water
connection
T connection
Cold water line to
untreated oven
connection
Treated cold
water to treated
connection on oven
ONE SUGGESTED
METHOD OF INSTALLATION
Water Filter
Cold water line to
filter or treatment
system
Install water
intake filters
Fig. 1