Electrical and Gas Supply Location with
Gas Cooktop over Wall Oven
Locate gas supply so manual shutoff valve is accessible
after installation. When installed in 25-inch deep
cabinets, electrical junction box and gas supply
should be installed in an adjacent cabinet. When
installed in a deeper cabinet (island), install according to
individual instructions. Manual gas shutoff valve must be
accessible after installation.
Electrical Connection Requirements
Line voltage must not exceed rated voltage. Line voltage
less than rated voltage will result in slow heating. Wiring
system must conform to U.L. Standards and National
Electrical Code. Installation must conform to all local,
municipal and state building codes, and local utility
regulations. Oven must be connected only to a supplied
circuit as specified on rating plate.
This oven requires 3 wires, 115/230-120/240 volts, 60
Hertz A.C. Unit is equipped with a No. 10 ground wire in
conduit. Oven should be fused separately from other
appliances on a 40 amp circuit minimum. Verify electric
power is off from fuse box to junction box until oven is
installed and ready to operate.
A 4-conductor box is to be used when the appliance is
installed where grounding through the neutral is
prohibited, such as: New branch – circuit installations
(1996 NEC), Mobile Homes, Recreational Vehicles, or in
an area where local codes prohibit grounding through
the neutral.
Power Supply Connection
WARNING
!
To avoid risk of electrical shock, personal injury, or
death, make sure cooktop has been properly grounded
and always disconnect it from main power supply
before any servicing.
To avoid risk of electrical shock or personal injury,
when connecting copper leads to aluminum house
wiring, use only connectors designed for joining
copper to aluminum. Follow connector
manufacturer’s recommendations closely.
To avoid risk of electrical shock or personal injury, do
not ground through neutral where prohibited such as
New Branch Circuit Installations (1996 NEC), Mobile
Homes, Recreation Vehicles or in an area where
local codes prohibit grounding through the neutral.
Oven has approximately 36 inches of flexible wire
conduit attached to rear. Approximately 6 inches of
green ground wire and 3 insulated wires, black, red,
and white extend beyond end of conduit. Connect wire
leads extending from conduit to house wires inside
junction box (Junction box not included). Refer to local
codes and attach according to options.
Option 1
Green
Oven Wire
Red or Black
Oven Wire
White
House Wir
e
Green
House Wire
Red or Black
House Wire
White
Oven Wire
4-Wire Electrical Connection
Option 2
White
House Wire
Red or Black
Oven Wire
Red or Black
House Wire
Green
Oven Wire
White
Oven Wire
3-wire Electrical Conection