Installing 4-Wire Power Cord
WARNING
To avoid the risk of severe electrical shock or death,
ground wire must be attached to frame of range, using
ground screw provided. Ground wire must not contact
any other terminal.
See Figure 8.
1. Remove rear wire cover on back of range.
2. Place strain relief (winged clamp) in cord access hole
below terminal block.
Strain relief is supplied with cord. Place wings
through hole entering from bottom.
Screw holes in clamp should be below mounting
panel.
3. Remove green ground screw (retain for use in step 8)
and unscrew brass nut on center terminal. Remove
grounding strap.
Green ground
screw
Center terminal
nut
Grounding
strap
Wires from range
(Number of wires on each terminal can vary)
Figure 8
4. Place cord through strain relief.
5. Attach cord neutral (center) or white wire to center
terminal on terminal block. Secure with hex nuts
provided. See Figure 9.
6. Attach power lead, red wire or black wire to left
terminal. Secure with hex nuts provided.
7. Attach power lead, red wire or black wire to right
terminal. Secure with hex nuts provided.
Wires from power cord
A
A
B
Wires from range
(Number of wires on each terminal can vary)
A—Power lead terminal (Connect black or red insulated
wire and secure with brass nut.)
B—Neutral terminal (Connect insulated white insulated
wire and secure with brass nut.)
Figure 9
8. See Figure 10. Position grounding strap down and
away from terminal block. Attach green or bare wire
and grounding strap to back of range using green
ground screw previously removed in step 3.
Wires from power cord
A
Wires from range
(Number of wires on each terminal can var
y
)
A—Ground screw (Connect green insulated wire and
secure with screw.)
Figure 10
9. Firmly tighten all connections to ensure proper
electrical connection.
10. Place screw through strain relief, tighten, and replace
rear wire cover.