What type of electrical
connection will you use?
Power Supply Cord:
Follow Option A instructions
Direct Wire:
Follow Option B instructions
Install strain relief
7
11
Remove terminal box cover
6
Using a ¹⁄₄” hex-head socket, nut driver or Phillips screwdriver,
remove terminal box cover. Retain for later use.
Install a UL Listed/CSA Approved strain relief. Check that the
screwheads are facing to the left when tightening conduit nut.
Strain relief may be provided with the power supply cord kit.
Option A, Power Supply Cord:
Route cord so that it does not touch dishwasher motor to lower
part of dishwasher tub. Pull cord through strain relief in terminal
bow.
Select UL Listed/CSA Approved twist-on wire connectors (not
included) rated to connect your household wiring to 16-gauge
dishwasher wiring.
Power Cord—Route cord
into terminal box
1
WARNING
Electrical Shock Hazard
Electrically ground dishwasher.
Connect ground wire to green ground connector
in terminal box.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Make Power Supply Cord Connection
Remove the green grounding screw and place
through the ring terminal of the green ground wire. Reattach
and tighten the green screw.
Ground
wire
Power Supply Cord—
Connect ground wire
2
Ground
wire
Washer
Ground
connector