(Continued)
PROBLEM CAUSE REMEDY
Main burners do not
ignite.
1. Gas control valve knob set to OFF or
PILOT.
2. Low gas supply pressure [less than 6
W.C. for natural gas; (11 W.C. for pro-
pane) when
all other gas-powered kitchen
equipment is operating].
3. Pilot burner problem.
4. Thermostat control set below the tem-
perature of the liquid shortening in the
kettle.
5. Gas control valve has failed.
1. Perform the normal Lighting
Procedure. Turn the gas
control valveknob to ON to
light the main burners.
If the burners do not light, the
gas control valve has failed and
must be replaced.
2. Measure the gas supply pres-
sure.
Contact your local gas supplier
to obtain adequate gas supply
pressure.
3. Refer to the preceding Pilot
Burner problems and use the
correct remedy.
4. Increase the thermostat setting
until the burners light. If this
setting is greater than the de-
sired temperature, reset the
thermostat to the desired set-
ting and allow the shortening to
cool to the desired tempera-
ture.
5. Replace the gas control valve.
Main burners do not
stop burning.
1. Thermostat has failed.
2. Gas control valve has failed.
1. Turn the thermostat control
knob to OFF. If the burners
do not quit burning, the ther-
mostat has failed and must
be replaced.
2. Turn the gas control valve knob
to OFF. If the burners do not
quit burning, the gas control
valve has failed and must be
replaced.