Anetsberger Brothers 14VF Fryer User Manual


 
5
!
Figure 2. Fryer Model 14VF/14VFS Site Installation Requirements
CODE REQUIREMENTS (Continued)
e. Install this fryer on a non-combustible floor
with its back and sides at least 6 away from
any combustible wall, as shown in Figure 2.
WARNING
Install this fryer under a ventilation
hood that conducts combustion pro-
ducts outside the building. Venting
must comply with ANSI/NFPA 96
(latest edition).
f. Install this fryer in a location where adequate
combustion and ventilation air is available.
Keep the area directly in front of the fryer open
for adequate air flow to the burners. DO
NOT obstruct the flow of combustion and
ventilation air.
g. Keep the fryer area free and clear from
combustibles and debris.
h. Attach a restraining device to each fryer, to
prevent the unit from tipping, which could
cause splashing of hot liquid .
From the top of the flue on
the fryer, allow a minimum
of
at least 10 inches verti-
cal clearance beneath a
ventilating hood.