Anetsberger Brothers 14VF Fryer User Manual


 
9
GAS CONNECTION INSTRUCTIONS
Installing your ANETS Fryer requires the fol-
lowing procedure, after its legs or casters are pro-
perly attached and it is in its desired location.
1. Ensure that the gas safety valve control knob
in the fryer has its OFF position next to the
valvemark.
2. Ensure that the gas supply inlet line valve is
closed (crosswise to the line direction).
3. Ensure that the fryer’s thermostat is set to
OFF.
4. Connect the ½ gas supply line to the gas line
adapter on the lower rear of the fryer.
5. Turn the gas supply line valve ON; then, check
all gas supply line joints and couplings for
leaks using soap suds or a leak-check solu-
tion, after the fryer is in its desired location.
6. Refer to Fryer Operation Recommenda-
tions and Fryer Operating Instructions to
begin using your ANETS Fryer.
CASTER LEVELING INSTRUCTIONS (Continued)
INSTALLATION REQUIREMENTS (Continued)
6. Reinsert each mounting screw through the
caster mounting plate; next, place a spacer of
the required size on the screw before inserting
the screw into the fryer mounting bracket.
7. Repeat step 6 for all remaining screws.
8. Tighten all four mounting screws evenly and
securely against the caster mounting plate into
the fryer bottom mounting bracket.
9. Return the fryer to its desired location. Lock
the front casters to prevent fryer movement
and check again for wobbling or rocking.
Repeat steps 4 through 8 until no wobbl-
ing or rocking occurs. When the fryer no
longer wobbles or rocks, perform step 10.
10. Next, perform the “Fryer Restraining
Device Installation Instructions.”
!
WARNING
DO NOT use a flame to check for leaks.