Belling BI Installation Instructions
30
Method 2: Housing unit with
internal height less than 710mm.
Note: You will not need the 2 side
trims (687mm long) or the appliance
runners for this installation. You will
need the 2 runners to fix to the
adjacent cabinets.
Before you start;
Before removing the bottom shelf or
modifying the housing unit, make sure
that it will remain structurally sound,
eg; by fixing to adjacent cabinets,
floor or worktop.
You may have to cut into or remove
any rear cross members to obtain the
550mm minimum depth.
To obtain the required 710mm height,
you may have to lower or remove the
bottom shelf - remove any cross rails
and reposition brackets.
To fix the runners (if required)
1. Take the side trims, hold it against
the side of the base unit, and use
it to mark off the 687mm from the
top edge of the side unit, to the top
edge for the runner.
Note: This ensures a 5 - 8mm
clearance from the underside of
the worktop to the top of the
appliance.
2. Measure 50mm from the front
edges of the base units, to mark
the front edge for the runners.
3. Take 6 of the No 8 x 12mm
(Black) chipboard screws and
screw the runners into position the
right way up as shown.
4. If necessary, adjust the height of
the plinth to just below the bottom
edge of the runners.
If you require a replacement fixing kit
please call 0844 815 3745 and
order part number 01 28287 00.