Bloomfield 9454 Beverage Dispenser User Manual


 
SERVICING INSTRUCTIONS
17
COLD WATER ADJUSTMENT
The dispenser can dispense both hot and cold beverage only
when connected to a water line with the water supply valve
open. Cold product is available from the left dispenser only, and
only when the COLD/HOT, HOT/ HOT selector switch is set in
COLD/HOT position.
1. Unplug power cord.
2. Remove right and left side panel. The cold water
adjustment is part of the inlet valve assembly. After panel
has been removed, plug the power cord back in and turn
the power switch ON.
3. RICHER (less water): Decrease the water flow by turning
the screw on the flow adjustment valve clockwise
(requires 5/32” hex key ). This results in less water in
the mixture.
LEANER (more water): Increase the water flow by turning
the screw on the flow adjustment valve counter-clockwise.
4. After adjustments are complete, unplug the power cord,
reassemble the side panels and plug the power cord back in.
Unit is now ready for normal operation.
CAUTION:
SHOCK HAZARD
Opening access panels may
expose uninsulated electrical
components.
Disconnect dispenser from
electrical power before
removing any panel. Do not
attempt to repair or replace
components without first
unplugging the power cord.
Use caution when adjusting
water flow rates or testing
voltages with power applied to
the unit. Electrical shock can
cause injury or death.