TROUBLESHOOTING (cont.)
Problem
Beverage level will not adjust
(Selector switch in any position)
Water flows into tank continuously
.
Water flows into tank continuously
(ON/OFF switch "ON").
Water from tank is not hot
Probable Cause
1. Brew Selector switch
1. Solenoid valve
2A. Level control board and level
probe (Electro/mechanical)
2B. Control assembly (Electronic)
1. Timer
2. Overflow protection switch
1. Limit thermostat
CAUTION - Do not eliminate or by-
pass limit thermostat. Use only re-
placement part #23717.0001
2A. Control Thermostat (Electro/me-
chanical)
2B. Control assembly (Electronic)
3. Contactor (Brewers with Recov-
ery Booster)
4. Tank heaters
5. Triac assembly (Electronic)
Remedy
Refer to
Service
- Selector switch for
testing procedures. See page 16
Refer to
Service
- Solenoid valve for
testing procedures. See page 36
Refer to
Service
- Level control board
for test procedures. See page 29
Refer to
Service
- Control assembly
for testing procedures. See page 23
thru 28
Refer to
Service
- Timer for testing
procedures. See page 39 or 42
Refer to
Service
- Overflow protec-
tion switch for testing procedures.
See page 33
Refer to
Service
-Limit thermostat
for testing procedures. See page 31
Refer to
Service