PROGRAMMING
Using the menu-driven display on the front of the brewer, the operator has the ability to alter or modify various
brewing parameters such as brew temperatures, brew volumes, bypass percentages, pulse brew, etc. This allows
for the precise brewing of various fl avors of coffee.
Programming of the brewer is achieved by entering a certain function. Then, by the use of hidden
programming switches and the brew/function buttons, the operator can customize the brewing process to their
specifi cations.
PROGRAMMING SWITCHES
To access the programming mode, and to scroll through the different function screens, hidden programming
switches are used. There are fi ve of these switches that will be used for the setup of the brewer.
a
b
c d e
a) Right Programming (hidden) button (just to the right of the display): This is used to access the program-
ming mode, and is also used to scroll forward through the function list.
b) Left Programming (hidden) button (just to the left of the display): This is used to scroll backwards through
the function list.
c) Brew A: This is used to select options that appear on the display during programming.
d) Brew B: This is used to select options that appear on the display during programming.
e) Brew C: This is used to select options that appear on the display during programming.
READY TO BREW
WATER TEMP: 200°
37077 101205
PROGRAMMING SWITCHES ------------------------------- 14
PROGRAMMING THE BREWER --------------------------- 15
FUNCTION FLOW CHART ----------------------------------- 16
BREW LOCKOUT -------------------------------------------- 17
SET LANGUAGE --------------------------------------------- 18
UNITS --------------------------------------------------------- 19
REVIEW RECIPES ------------------------------------------- 20
ASSIGN RECIPE --------------------------------------------- 21
DISABLE BREW SWITCH ------------------------------ 21
SET NEW RECIPE (USING A SMART ------------------------
FUNNEL AND GRINDER) ------------------------------- 22
SET NEW RECIPE (USING RECIPE CARD) --------------- 24
SET NEW RECIPE (NO SMART FUNNEL, --------------------
GRINDER OR RECIPE CARD) -------------------------- 25
REVIEW/MODIFY/SETUP RECIPE
BREW OZ ------------------------------------------------ 26
DISABLE BATCH SIZE ---------------------------------- 26
% BYPASS ----------------------------------------------- 27
PROGRAMMING SECTION
PULSE BREW -------------------------------------------- 28
DRIP TIME ----------------------------------------------- 32
SET TEMP ---------------------------------------------------- 33
READY DEGREE --------------------------------------------- 34
ENABLE ADS ------------------------------------------------- 35
ENABLE SANITATION --------------------------------------- 37
ENABLE ENERGY SAVER ----------------------------------- 38
ENABLE FRESHNESS TIMER ------------------------------ 39
REFILL -------------------------------------------------------- 40
FLOW RATES ------------------------------------------------- 41
CALIBRATE FLOW ------------------------------------------- 43
BREW COUNTERS ------------------------------------------- 45
ASSET NUMBER --------------------------------------------- 46
SERVICE NUMBER ------------------------------------------ 47
SERVICE TOOLS --------------------------------------------- 48
FACTORY DEFAULTS ---------------------------------------- 52
DEFAULT SETTINGS ----------------------------------------- 53