PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
CALIBRATE FLOW
This function allows the operator to enter the actual
fl ow rate of the sprayhead and the bypass by dispens-
ing both separately for one minute. The volumes are
then entered into the brewer.
Procedure to calibrate the sprayhead fl ow rate:
1. Place a container, accurately graduated and with a
minimum capacity of 60 ounces, beneath the fun-
nel.
2. Press and hold the right hidden button until the
display reads SET LANGUAGE. Press the right
hidden button until the display reads CALIBRATE
FLOW.
3. Press and release YES to advance to the SPRAY
HEAD CAL function screen. (Pressing NO in the
CALIBRATE FLOW screen will advance to the next
function screen, BREW COUNTERS).
4. Press and release the YES pad. The display should
read CONTAINER READY? If the container is under
the funnel, press YES.
5. The display should read CALIBRATE SPRAY. Press
and release START to begin the sprayhead fl ow for
calibration. The display should read CALIBRATE
SPRAY...60 SEC TO FINISH. The 60-second timer
on the display will count down to zero. When the
counter reaches zero, the display will change to
SPRAYHD OZ/M, along with a number.
6. Measure the amount of water in the container and
use the (-) and (+) pads to adjust the amount of
the display to match the amount in the container.
Then press DONE.
7. The display should now read NEW SPRAY FLOW,
along with the correct fl ow rate of the sprayhead.
After about 5 seconds, the display will return to the
CALIBRATE FLOW SCREEN
8. To exit the CALIBRATE FLOW function and advance
to the next function screen, press and release NO.
To exit programming, press and release the ON/OFF
button to return to the MAIN SCREEN.
P3095
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
CALIBRATE FLOW?
NO YES
SPRAY HEAD CAL
NO YES
CALIBRATE FLOW?
NO YES
CONTAINER READY?
QUIT YES
CALIBRATE SPRAY
QUIT START
CALIBRATE SPRAY
60 SEC TO FINISH
SPRAYHD OZ XX.X
(-) DONE (+)
NEW SPRAY FLOW
XX.X OZ/M
PRESSING NO WILL
ADVANCE TO
BREW COUNTERS
PRESSING NO WILL
ADVANCE TO
BREW COUNTERS
5 SEC.