TROUBLESHOOTING (cont.)
PROBLEM PROBABLE CAUSE REMEDY
Water fl ows into tank continuously
with power removed from brewer.
1. Refi ll valve
2. Refi ll probe or sensitivity set-
ting
3. Control Board
Foreign material lodged in valve,
holding it in open state.
Check the sensitivity setting. Refer
to the REFILL function on page
40. If the left three digit number
is less than the right number, the
machine “thinks” it is full and the
refi ll valve should be off. If the left
number is larger than the right, then
the refi ll valve will automatically be
turned on to fi ll the tank. The right
number is the threshold setting and
can be adjusted to compensate for
extreme water conditions: very pure,
low conductance water requires a
higher setting, while high mineral
content, high conductance water
requires a lower setting. Note that
the left number changes from a high
value when water is NOT touching
the refi ll probe to a low valve when
water IS touching the probe. For
best operation, the right number
should be set to a value midway
between these low and high num-
bers. Before changing the setting,
confi rm that the refi ll probe is free
of scale buildup and the connection
to it is secure.
Substitute a control board known
to be in good working order.