Bunn ICB-DV Coffeemaker User Manual


 
Page 44
PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
CALIBRATE FLOW (Continued)
Procedure to calibrate the bypass fl ow rate:
1. Place a container, accurately graduated and with a
minimum capacity of 60 ounces, beneath the fun-
nel.
NOTE: If the display is already on the BYPASS CAL
screen, skip steps 2 & 3 and proceed directly to step
4.
2. Press and hold the right hidden button until the
display reads SET LANGUAGE. Press the right
hidden button until the display reads CALIBRATE
FLOW.
3. Press and release YES to advance to the SPRAY
HEAD CAL function screen. Press and release NO
to advance to BYPASS CAL.
4. Press and release the YES pad. The display should
read CONTAINER READY? If the container is under
the funnel, press YES.
5. The display should read CALIBRATE BYPASS. Press
and release START to begin the fl ow for calibration.
The display should read CALIBRATE BYPASS...60
SEC TO FINISH. The 60-second timer on the display
will count down to zero. When the counter reaches
zero, the display will changes to BYPASS OZ/M,
along with a number.
6. Measure the amount of water in the container and
using the (-) and (+) pads, adjust the amount of
the display to match the amount in the container.
Then press DONE.
7. The display should now read NEW BYPASS FLOW,
along with the correct fl ow rate of the bypass.
After about 5 seconds, the display will return to
CALIBRATE FLOW SCREEN. To exit programming,
press and release the ON/OFF button to return to
the MAIN SCREEN.
P3096