Bunn LCA-2 LCC-2 Coffeemaker User Manual


 
11
34766 112502
Rinse Alarm Feature
Periodic rinsing of the mix chambers and dispense tips is essential for proper maintenance and optimum
performance of the dispenser. The automated Rinse Alarm feature has three levels of operation, Disabled, Warning
Only and Warning with Brew Lockout, see chart for details.
Alarm Level Selected Alarm Mode
Disabled None
Warning Only Rinse LED will come on 4 hrs prior to the selected time interval and remain on
until the Rinse procedure has been performed. The dispenser will continue to
serve product.
Warning w/ Brew Lockout Rinse LED will come on 4 hrs prior to the selected time interval and remain on
until the Rinse procedure has been performed. The dispenser will Lockout and
not continue to serve product once the selected time interval has elapsed.
NOTE: The time interval between Rinses is adjustable from 8 to 24 hrs.
The dispenser is shipped with the automated Rinse Alarm disabled, (No Alarm). It is up to the user to determine
the Rinse time interval and the level of warning required, based on their application and maintenance procedures.
To enable the automated Rinse Alarm feature, refer to RINSE ALARM ? in
Programming the Dispenser.
Rinse Procedure:
1. Open the cabinet door and select Rinse on the Function Selector switch – close the door.
2. Place a 2 Liter (1/2 Gal) container under the Left dispense tip.
3. Pull the Left dispense handle until water flow stops automatically, approximately 20 sec. per side.
4. Repeat Steps 2 & 3 for the Right dispense tip.
The Rinse LED will turn OFF, when the Rinse procedure has been satisfied for both sides.
5. Open the cabinet door and select Normal on the Function Selector switch – close the door.
Brew Temperature Lockout Feature
The dispenser can be set to not dispense product if the hot water is not up to the preset READY temperature. To
enable this feature set the READY temperature to the minimum allowable dispense temperature. Then enable the
Brew Lockout feature, refer to READY TEMP and BREW LOCKOUT, in
Programming the Dispenser.