OVERFLOW CUP
FULL. EMPTY CUP
HEATING TIME TOO
LONG
CHECK HEATING
CIRCUIT
FILL TIME TOO LONG
CHECK WATER
SUPPLY
TANK TEMP SENSOR
OUT OF RANGE
CHECK FOR BAD
CONNECTIONS
COOL TEMP SENSOR
OUT OF RANGE
CHECK FOR BAD
CONNECTIONS
1. Refill valve stuck open
2. Faulty refill probe
3. Faulty overflow switch
1. Tank Heater failure
2. Triac failure
3. Tank Temp. sensor failure
1. Water shut off to dispenser
2. Inlet Solenoid Valve failure
1. Corresponding Temperature Sensor
Probe wire(s) broken or disconnected
1. Corresponding Temperature Sensor
Probe wire(s) broken or disconnected.
Service Required
Service Required
Service Required
Service Required
Service Required
Service Required
Check water supply shut-off
Service Required
Service Required
Service Required
Screen Displayed Possible Cause Troubleshooting Procedures