Bunn LCA-2 LCC-2 Coffeemaker User Manual


 
14
SET PASSWORD ?
(-) 0 (+)
SELECT UNITS
ENG EXIT METRIC
CHILLED UNIT ?
NO EXIT YES
RINSE ALARM ?
NO EXIT YES
MENU SCREEN ACTION DESCRIPTION
CAL LEFT PUMP ?
PULL DISPENSER
CAL LF PUMP VOL
(-) 20mL (+)
CAL LF WTR FLOW
PULL DISPENSER
If NO - go to CAL RIGHT SIDE menu.
CAL LEFT SIDE ?
EXIT YES
The following functions are for diagnostic and troubleshooting purposes and typically do not have to be
adjusted. Contact your local service agent for assistance before making changes to these functions.
RINSE TIME ?
(-) 12 Hrs (+)
RINSE LOCKOUT ?
EXIT YES
BREW LOCKOUT ?
EXIT YES
If NO - go to BREW LOCKOUT menu.
Pull the Left dispenser handle
Use the (+) or (-) buttons to
enter volume collected
Place a 64 Oz. (2000 mL)
container under the Left
dispenser, then pull the handle
Select (YES) to enable
Use the (+) or (-) buttons to
adjust Rinse Alarm delay
Select (YES) to enable
Select (YES) or (NO)
Use the (+) or (-) buttons to
change the password.
Select the preferred units
Select (YES) or (NO)
Select (YES) or (NO)
The Left Pump will dispense concentrate for 20
seconds, then shut off automatically. Collect and
measure the concentrate dispensed.
Enter the volume of concentrate measured from
the Left Pump in mL, (not Oz.) regardless of
Preferred Units selected.
The Left Dispenser will dispense hot water for 20
seconds, then shut off automatically. Collect and
measure the water dispensed.
Selecting Yes will enable the Left Dispenser
Calibration routine, (see
Field Calibration
before
attempting to calibrate the dispenser).
Enter the desired time between required Rinse
Cycles in hours, [8 - 24 hrs.]
Select YES to Lockout dispensing until the Rinse
Alarm has been cleared. Default is NO
Select YES to Lockout dispensing until the hot
water tank is at READY Temp. Default is NO
Enter your own Code to prevent access to the
remaining functions. [0 to 9999]
Used to select the preferred units of measurement.
(Oz., Gal, deg F) or (mL, L, deg C)
LCA Models without Chiller select (NO)
LCC Models with Chiller select (YES)
Selecting Yes will enable the Rinse Alarm function,
(see
Rinse Alarm
)
34766 112502