Bunn LCA-2 LCC-2 Coffeemaker User Manual


 
16
MENU SCREEN ACTION DESCRIPTION
BIB EMPTY -> 400
(-) EXIT (+)
0 REFILL -> 155
(-) EXIT (+)
WTR START DELAY
(-) .15SEC (+)
WTR STOP DELAY
(-) .15SEC (+)
TEST LED’S ?
NO EXIT YES
TEST SWITCHES ?
UseSwitchToTest
TEST REFILL ?
EXIT YES
TEST HEATER ?
EXIT YES
FACTORY DEFAULTS
NO YES
Use the (+) or (-) buttons to
adjust empty BIB threshold
Use the (+) or (-) buttons to
adjust Refill threshold
Use the (+) or (-) buttons to
adjust delay time
Use the (+) or (-) buttons to
adjust delay time
Select (YES) or (NO)
NONE
Momentarily depress (YES)
Momentarily depress (YES)
Select (YES) or (NO)
Used to set the Conductance Threshold for the
Empty BIB warning.
Used to set the Conductance Threshold for the
Tank Refill Probe.
Dispense Valve ON Delay. Eliminates weak mix at
the beginning of a dispense.
Dispense Valve OFF Delay. Flushes the mix
chamber at the end of a dispense.
LED diagnostics. Selecting YES will light all Front
Door LED’s.
Switch Diagnostic: Activate switches separately
to test. Display will indicate which Switch has
been activated. NOTE: Door Interlock switch must
be held closed.
Refill Valve Diagnostic: Press YES to momentarily
energize the Solenoid. CAUTION: Inlet Valve will
open and water will flow, if connected and turned
ON.
Tank Heater Diagnostic: Press YES to momentarily
energize the Tank Heater Circuit.
CAUTION: AC power will be applied to the Tank
Heater Circuit.
CAUTION: Selecting YES will RESET all
Programming Functions to the Factory Default
settings. NOTE: On LCC Models the Chiller will
have to be reset to the ON condition, (see
Chilled
Unit
programming function).
34766 112502