Bunn SLCA-7 Coffeemaker User Manual


 
15
CLEANING & PREVENTATIVE MAINTENANCE
General Cleaning and Sanitizing Procedures Note: The BUNN¨ SLCA-7 dispenser incorporates a “user select-
able” rinse reminder feature, which flashes the LED’s on the front panel when it is time to rinse.
Daily: RINSING
1. Open the front door and place the Normal/Program/Rinse switch in the RINSE position.
2. Place a ½ gal (2 liter) container under the dispense nozzle. Press any dispense button on the front door. The
LED display above the programming switches will begin counting down from “8”. The rinse will terminate
when the display reaches “0”.
3. Return the Normal/Program/Rinse switch to the NORMAL position, and close the front door.
Daily: PARTS WASHING
1. Remove and wash the drip tray and drip tray cover in a mild detergent solution. Rinse thoroughly.
2. Wipe the splash panel, dispense nozzles, door, and cabinet with a clean damp cloth.
Weekly: SANITIZING
1. Open the dispenser door.
2. Select PRIME on the Function Selector Switch and RUN on the Mode Selector Switch.
3. Remove the bag connector from the product BIB and disassemble or prop open the internal valve to allow
flow of product through the connector.
NOTE: Cutting the mating fittings from an empty bag makes an excellent “free flowing” connector for this purpose.
4. Place the bag connector into a one-gallon (3.8 liter) container of warm soapy tap water 140°F (60°C).
5. Place an empty container under dispense tip and activate the corresponding pump until the clean soapy water
is dispensed from the dispense tip.
6. Repeat steps 4 and 5 with warm tap water 140°F (60°C) to rinse the soapy water from the pump tubing.
Continue dispensing until the water is clear, and no soapy water is being dispensed.
7. Prepare 2.5 gallons (9.46L) of sanitizing solution by dissolving 1 packet of Kay 5 sanitizer into 2.5 gallons
(9.46L) of 120°F (48.9°C) water to ensure 100 ppm of available chlorine.
8. Again, repeat steps 4 and 5 with the sanitizing solution. Once sanitizing solution is visible, continue to dispense
for 1 minute. Release handle and allow solution to sit for 5 minutes.
9. After soaking for 5 minutes, activate the dispense switch a second time, this time for 2 minutes. After 2
minutes, release the dispense switch.
10. Repeat step 6 to flush out the sanitizing solution from the pump tubing.
11. Remove the mating connector from the bag connector.
12. Reattach the bag connector to product box.
13. Select NORMAL on the Function Selector Switch and RUN on the Mode Selector Switch.
14. Activate the dispenser until concentrate/water mixture appears. Then dispense 12 ounce (354.9 ml) glass of
concentrate/water mixture and discard.
15. Repeat steps 1 through 14 for other dispense head.
16. Wipe internal and external surfaces with a clean, damp cloth.
39328.3 012113