CALIBRATING THE DISPENSER
CALIBRATION MODE: The SLCA-7 is calibrated at the factory and does not normally need to be re-calibrated.
To enter the Calibration Mode, Set the RUN/NIGHT/PROGRAM Switch to the PROGRAM position and then hold
the MENU switch down for 10 seconds.
LED DISPLAY CALIBRATION MODE DESCRIPTION
MENU (-) (+)
1C
r u n
MENU (-) (+)
1C
4 0
0
MENU (-) (+)
2C
r u n
2C
4
MENU (-) (+)
3C
r u n
MENU (-) (+)
3C 41
Left Pump Cal.
Left Pump Cal.
Right Pump Cal.
Right Pump Cal.
Left Coffee Water Rate
Left Coffee Water Rate
Set PRIME-NORMAL-RINSE switch
to PRIME position.
Press the SMALL button, left pump
will run for 100 counts
Enter ml collected from the 100 count
test above.
Default = 43.0 ml
Set PRIME-NORMAL-RINSE switch
to PRIME position.
Press the LARGE button, left pump
will run for 100 counts
Enter ml collected from the 100 count
test above.
Default = 43.0 ml
Set PRIME-NORMAL-RINSE switch
to RINSE position
Press the SMALL button, left pump
dilution water will run for 20 seconds.
Enter Liters collected from 20 sec.
test above
Default = .414