Bunn SLCA-7 Coffeemaker User Manual


 
16
Weekly: Parts Washing and Sanitizing
39328.3 012113
14. When reassem-
bling parts, be sure
to align arrow on
frother disk with
flat on whipper mo-
tor shaft, and rotate
tab on whipper base
clock wise to the
vertical position to
lock mixing cham-
ber.
10. Remove dispense
hoses from dispense
nozzle assembly.
9. Rotate tab on mix-
ing chamber base
further counter clock
wise, and remover
from shaft by pulling
straight out.
NOTE: Insure O-ring and
shaft seal are in place
during re-assembly.
7. Remove middle and
right frother disk
from shaft by pulling
straight out.
6. Remove mixing
chambers by pulling
straight out.
5. Rotate tab at bottom
of mixing chamber
bases counter clock
wise to release base.
2. Remove elbows from
middle and right mix-
ing chambers, twist-
ing slightly to help
release.
1. Remove elbows from
both hoppers.
11. Clean all parts re-
moved in warm soapy
water. Use Bunn P/N
33685.0000 clean-
ing brush provided
to clean bores and
orifices. Rinse in cold
water.
12. Prepare one-gallon
(3.8 liter) of sanitiz-
ing solution with at
least 100 ppm of
available chlorine in
120°F (48.9°C) wa-
ter.Soak all cleaned
parts in sanitizing so-
lution for 5 minutes,
then rinse thoroughly
in cold water, and
dry.
13. Rinse cleaning
brush, dip in sani-
tizing solution, and
brush the bore of
each of four dis-
pense nozzles.
NOTE: Repeat this pro-
cedure for each nozzle
separately.
3. Remove dispense
hose from left whip-
ping chamber by
sliding it to the right.
4. Remove upper mix-
ing bowl from left
chamber by pulling
out and up.
8. Remove left frother
from shaft by pulling
straight out.
15. When reassembling
left frother, be sure
to align raised bar
on top of frother
shaft with the flat
on whipper motor
shaft.