INSTALLATION INSTRUCTIONS
10
Power Requirements:
120 VAC, 60 Hz., single phase.
CT-304/CT-365: 0.10 Amp. Max.
(Use 15 Amp. circuit minimum)
Always disconnect the electric supply cord from the wall outlet or turn off the electricity at the
service disconnect before servicing this appliance.
Observe all governing codes and ordinances when grounding, in the absence of which, observe
National Electrical Code ANSI/NFPA No. 70-1990.
Recommended Grounding Method:
This appliance is factory equipped with a power supply cord with a three-prong grounding plug (with
polarized parallel blades). It must be plugged into a mating grounding-type receptacle, connected to
a correctly polarized 120 Volt circuit. If the circuit does not have a grounding type receptacle, it is the
responsibility and obligation of the installer or user to have the existing receptacle changed to a
properly grounded and polarized receptacle in accordance with all applicable local codes and
ordinances by a qualified electrician. In the absence of local codes and ordinances, the receptacle
replacement shall be in accordance with the National Electrical Code. THE THIRD GROUND PRONG
SHOULD NOT, UNDER ANY CIRCUMSTANCES, BE CUT OR REMOVED. The electrical supply must be a
120 volt, 60 Hz single phase, 15 AMP circuit. The power receptacle must be a NEMA 5-15R device to
accept the three prong plug supplied with the unit.
THIRD GROUND PRONG
COUNTER TOP
GAS SUPPLY
Installer supplied
shut-off valve must
be easily accessible
inside cabinetry
ELECTRIC SUPPLY
4 FOOT POWER CORD
COUNTER TOP
GAS SUPPLY
Installer supplied
shut-off valve must
be easily accessible
inside cabinetry
ELECTRIC SUPPLY
4 FOOT POWER CORD
90
0
Elbow
supplied*
(CT-304
only)
• Required when unit is installed over Wall Oven
REGULATOR
REGULATOR
GAS CONNECTION FOR CT-365
GAS CONNECTION FOR CT-304