DCS T-365BK Cooktop User Manual


 
INSTALLER FINAL CHECKLIST
11
GENERAL
Placement of Unit.
Specified clearance maintained to cabinet
surfaces.
Unit Level- front to back, side to side.
All packaging material and tie straps
removed.
ELECTRICAL:
Receptacle with 15 ampere circuit
protection is provided for service cord
connection.
Adequate ground connection.
GAS SUPPLY:
Connection: 1/2 NPT with a minimum 5/8”
diameter flex line.
The pressure regulator which is connected
to the manifold is set for 4.0”W.C. for Natural
Gas or 10”W.C. for LP.
Manual gas shut-off valve installed in an
accessible location.
Unit tested and free of gas leaks.
OPERATION:
All internal packing materials are removed,
i.e. below grates, around knobs, etc.
Bezels centered on burner knobs and knobs
turn freely.
Each burner lights satisfactorily, both
individually and with other burners
operating.
Low flame operation verified.
All burner caps, burner rings and burner
bases correctly seated in position, level, and
do not rock or slide.
Burner grates correctly positioned, level, and
do not rock.