INSTALLER FINAL CHECKLIST
11
GENERAL
❏ Placement of Unit.
❏ Specified clearance maintained to cabinet
surfaces.
❏ Unit Level- front to back, side to side.
❏ All packaging material and tie straps
removed.
ELECTRICAL:
❏ Receptacle with 15 ampere circuit
protection is provided for service cord
connection.
❏ Adequate ground connection.
GAS SUPPLY:
❏ Connection: 1/2 NPT with a minimum 5/8”
diameter flex line.
❏ The pressure regulator which is connected
to the manifold is set for 4.0”W.C. for Natural
Gas or 10”W.C. for LP.
❏ Manual gas shut-off valve installed in an
accessible location.
❏ Unit tested and free of gas leaks.
OPERATION:
❏ All internal packing materials are removed,
i.e. below grates, around knobs, etc.
❏ Bezels centered on burner knobs and knobs
turn freely.
❏ Each burner lights satisfactorily, both
individually and with other burners
operating.
❏ Low flame operation verified.
❏ All burner caps, burner rings and burner
bases correctly seated in position, level, and
do not rock or slide.
❏ Burner grates correctly positioned, level, and
do not rock.