Electrolux AOW101E Convection Oven User Manual


 
18
5958 992 00
EN
8. BRIEF TROUBLESHOOTING GUIDE
Even with correct use, malfunctions can occur.
Oven compartment heating does not switch on or is ineffi-
cient. Possible causes:
- Oven compartment temperature limiter activated
- Heating elements damaged
- Element contactor coil damaged
- Oven compartment temperature probe damaged (error EPt1 con-
figuration).
- Controller damaged
- Fuse F2 blown, see wiring diagram.
- MAGNETRON limiters activated.
The steam generator heating does not switch on or is ineffi-
cient in steam production. Possible causes:
- Heating elements damaged
- Element contactor coil damaged
- Controller damaged
- Fuse F2 blown
- No water in system
- Boiler drain closing device faulty
- Water inlet solenoid valves damaged (they do not open)
Incorrect oven compartment temperature thermostatting.
Possible causes:
- Electronic controller faulty.
- Oven compartment temperature probe dirty, faulty or discon-
nected, see error EPt1 configuration.
The oven goes off. Possible causes:
- Fuse F2 blown due to damaged auxiliary circuit components.
Oven compartment lamps damaged
Important: Switch the appliance off before changing oven com-
partment lamps.
9. POSITIONING OF MAIN COMPONENTS
(Any operation inside the appliance must only be carried out
by an installer authorized by the Manufacturer)
Open the control panel to access the following components:
Danger: Live voltage is present with panels removed and unit
switch on. Exercise extreme caution when work with live voltage.
- Electronic boards.
- Compartment temperature limiter thermostat.
- Fuses.
- Door safety microswitch.
- Transformer for compartment lamps
- Compartment vent shutter control gear motor
WARNING: Before servicing unit switch off power at the main
circuit breaker and place a red tag on the breaker to indicate work
is being done on the circuit.
Remove the appliance left, right and rear panels to access to all