26
5958 992 00
EN
3) First, press the button P2 ( ) several times to select the time
field
.
P2 P3
then press the button P3 (
) to display the CORE PROBE field
and set the required temperature with knob K.
The starting value is 50°F "10°C"( max 210°F "99°C").
(display without TIMED PHASES)
65
E.g.
SET CORE PROBE
TEMPERATURE 65°C
(display with TIMED PHASES)
65
1 30
:
E.g.
TOTAL TIME _____
______
FOR PHASES 1 hour and 30 minutes
4) Starting the cycle.
- make sure the oven door is closed;
- Press the START/STOP button (the message PREHEAT ap-
pears)
Preheating is automatic for any cooking cycle set; to skip it, press
the button P3 (
) or go to the next point.
- Wait until the compartment temperature field indicates the reach-
ing of preheating temperature (the message LOAD appears).
- Open the door and introduce the product to be cooked.
Caution! Risk of burns.
Always open the door with caution when the oven is hot.
Remove the core probe “C” from its seat “D” and insert it in the
product without forcing excessively, making sure the tip (the sen-
sitive part) is positioned near the center of the product.
MULTIPOINT 6-sensor core probe
4.4.2 SETTING COOKING TEMPERATURE
1) Press the button P2 (
) several times to select the compart-
ment cooking TEMPERATURE field
and set it as required with
knob K.
E.g.
COMPARTMENT
TEMPERATURE 300°F
300
0
0
P1 P2
Note
The steam cycle has an operating temperature automatically
set to212°F (100°C). Low temperature steam can be set from
77°F (25°C) to 211°F (99°C) by turning the corresponding knob.;
superheated steam (temperature from 213°to 266°F) (from101°
to 130°C).
4.4.3 SETTING COOKING TIME
1) Press the button P2 ( ) several times to select the cooking
TIME
field of the phase and set that required with the knob K.
(display with one TIMED PHASE)
1 00
:
Eg.: (TIMED PHASE)
TIME 1 hour
(display with several TIMED PHASES)
Eg.:
1 00
:
2 30
:
TOTAL REMAINING_________
TOTAL PHASES
2 hours and 30 minutes
4.4.4 SETTING AND USE OF CORE PROBE (PRODUCT CORE
TEMPERATURE CONTROL)
The core probe allows accurate control of the core temperature
of the product being cooked. This allows setting of the required
value and automatic stopping of cooking when that value is
reached.
Important: The core probe is a precision component.
Absolutely avoid impacts, forcing when inserting and
pulling of the flexible cable (in particular when using the
trolley-mounted structures). The warranty does not cover
the replacement of core probes damaged due to improper
use.
1) Switch the oven on.
2) Select the required cooking mode (4.4.1SELECTING COOK-
ING MODE) and set the cooking temperature in the field .