Electrolux CHI 950 Ventilation Hood User Manual


 
8
Before carrying out any maintenance or cleaning isolate the cooker hood from the mains supply.
Charcoal Filters
In the recirculation mode the charcoal lters absorb smells and unwanted odours.
Enabling the alarm signal
• In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or at a later date.
• Turn the Lights and the suction Motor off.
• Disconnect the Hood using the Main switch or the double-pole switch on the mains power supply.
• Restore the connection by pressing and holding T1.
• Release the button. All ve LEDs are turned on
• Within 3 seconds press T1 until LEDs T1 and T4 ash in con rmation:
LED ashes twice - Activated charcoal lter saturation alarm ENABLED
LED ashes once - Activated charcoal lter saturation alarm DISABLED
The lter is not washable and cannot be regenerated. It must be replaced when led S1 ashes or at least every
4 months. The alarm signal will only light up when the extractor motor is switched on.
To Remove/Replace the Charcoal Filters
Remove the metal grease lters
Remove the saturated activated carbon lter by
releasing the xing hooks
Fit the new lter by hooking it into its seating
Replace the metal grease lters.
This appliance can be a possible re
hazard if the grease and charcoal lters
are not cleaned and replaced as recommended.
Alarm signal reset
• Switch off the lights and extractor motor.
• Press button T3 for at least 3 seconds, until the
leds start to ash.
Changing the Light halogen
• Remove the snap-on lamp cover by levering it from
under the metal ring, supporting it with one hand.
• Remove the halogen lamp from the lamp holder by
pulling gently.
Replace the lamp with a new one of the same type,
making sure that you insert the two pins properly into
the housings on the lamp holder.
• Replace the snap-on lamp cover.
MAINTENANCE AND CLEANING