18
Installation
INSTALL THE HOOD
1 Raise the hood into its mounting position.
2 Align the rectangular opening on the back of the hood with the wall-mounting
bracket. Gently lower the hood until it securely engages the bracket. Figure 14.
3 Level the hood with (2) 3.9x9.5mm mounting screws and secure with (2) 4.8x38mm
mounting screws. Use drywall anchors provided if wall studs or framing are not
available. Figure 14.
4 Mount the electrical system plate attaching it with (3) 3.9x9.5mm mounting screws.
Figure 15.
5 On ducted hoods, attach 6” round metal duct between the hood’s blower collar
and duct that leads to the outside location.
6 On non-ducted hoods, attach 5” round metal expandable duct between the 5”- 6”
adapter on the hood the connector on the plenum.
7 Tape all duct joints to make them secure and air tight.
8 Plug the power cord into the electric wall receptacle. Tuck excess cord behind the
flue.
MOUNTING
SCREWS
(4.8x38mm)
MOUNTING
SCREWS
(4.8x38mm)
RECTANGULAR
OPENING
WALL
MOUNTING
BRACKET
MOUNTING
SCREWS
(3.9x9.5mm)
PLATE OF THE
ELECTRICAL
SYSTEM
MOUNTING
SCREWS
(3.9x9.5mm)
Figure 14 Figure 15
NOTE
At least two people will be required to mount the hood.