ITEMS FOR CONSIDERATION
• Locate the unit as close to the indoor
section as possible. (See Tubing
Specications chart on pape 7.)
• If the unit is used for low ambient cool-
ing down to 32°F, this option must be
specied to prevent system damage.
• Avoid high trafc areas and prevailing
wind locations.
• Surface must be at and level.
• Mount unit above typical snow fall
levels.
Ensure free ow of air through the unit.
Air must not recirculate from discharge to
intake. Air is drawn through the coil and
side discharged through the fan grille. A
minimum 48" clearance is necessary for
the condenser discharge. Rear intake
(coil side) clearance is 12" minimum.
Consider how power will be run to the unit
from the power source. Refrigerant piping
should be a direct line to the indoor unit.
SITE PREPARATION
1. Place the unit on a at concrete surface
or pad if on the ground. Roof mounting
should use a build up platform to avoid
intake of hot air from the roof.
2. In areas of heavy snowfall, condens-
ers should be set above the level of
maximum anticipated snowfall (12"
is usually adequate).
1. Loosen the screws on left and right sides
of the front panel. (Do not remove these
screws.)
2. Remove the screws on the front of the
panel.
3. To remove front panel:
4. Slide front panel forward to clear side
screws and remove.
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
S1C is shown
UNIT MOUNTING INSTRUCTIONS
Side discharge unit allows for per-
manent mounting through the feet. This is
highly recommended due to the vertical
design of the unit.
SYSTEM OPTIONS (cont.)
void the warranty. A Field Installed Low-
Ambient Kit is good for operation down to
32º F.
This is accomplished by cycling the
condenser fan on and off, which will in turn
maintain a constant low side pressure pro-
viding a steady cooling effect and keeping
the air handler from frosting-up.