Natural gas LPG
Test Point Pressure [kPa] 1.0 2.75
BURNER
Injector
Orifice Dia.
[mm]
Gas
Consumption
[MJ/h]
Injector
Orifice Dia.
[mm]
Gas
Consumption
[MJ/h]
Auxiliary
0.85 3.60 0.53 3.60
Semi-rapid
1.12 6.30 0.70 6.30
Triple-ring wok
1.60 12.70 0.95 11.90
FOUR FUNCTION MODELSGAS COOKTOP MODELS
Adjusting the minimum burner setting
Check whether the flame spreads to all burner ports when the
burner is lit with the gas valve set to the minimum position.
If some ports do not light, increase the minimum gas rate
setting. Check whether the burner remains lit even when the
gas valve is turned quickly from the maximum to the minimum
position. If the burner does not remain lit, increase the
minimum gas rate setting.
To adjust the minimum gas rate setting:
1
Turn on the burner.
2
Turn the valve to the MINIMUM position.
3
Take off the knob.
4
Using a small flat screwdriver, turn the screw (see Figs. 13 or 14)
to the correct regulation.
Note: for LPG, the regulation screw is normally tightened up.
Table for the choice of injectors
Fig. 14 Adjusting the minimum burner setting:
seven-function models (Note: valves may vary)
regulation screw
Fig. 13 Adjusting the minimum
burner setting: four-function models
regulation screw
OR