WHAT TO DO IN CASE OF AN ANOMALY
PROBLEM SOLUTION
The oven does not work. Check whether the omnipolar switch or any
residual-current circuit breaker (cut-out) of the
electrical system is off. In case of problems with the
electrical system, consult a qualified electrician. If
the oven still does not work after resetting the
omnipolar switch and/or residual-current circuit
breaker, contact an Authorized Service Centre.
The light inside the cooking chamber does
not turn on.
See the instructions on how to change the oven light
bulb.
The display shows Err and a number. This combination indicates a failure.
See the error codes table on the following page.
The system requires the time to be set. Probable electricity failure (Black-out).
Set the current time.
The draining of the water from the boiler
occurs a long time after the end of a cooking
process.
For safety reasons the water from the boiler is
pumped away only when the temperature has
dropped below 90°C.
The time necessary for the water to cool determines
the pause before the draining starts.
(this may last up to 20 min.)
During this time, another cooking process can be
started.
Steam comes out of the oven during
operation.
Check whether the door is closed correctly.
Check whether the seal is damaged with cracks, etc.
In the second case, contact an Authorized Service
Centre.
The system displays a food probe temperature
during operation without the food probe
connected.
Check the seal of the food probe connector cap
inside the cooking chamber.
If the cap is unstable, it must be replaced.
Contact an Authorized Service Centre.
WHAT TO DO IN CASE OF A BLACK-OUT
In the case of a black-out, when the electricity is restored it may be necessary to reset the current
time.
The stored settings or recipes are not lost.
If the black-out occurs during a cooking process, the process cannot continue.
If a descaling or boiler cleaning process was in progress before the black-out, the process is aborted.
When the electricity is restored, it will be necessary to drain the solution of water and citric acid
monohydrate contained in the boiler. Follow the instructions shown on the display of the appliance.
82