Franke Consumer Products SM 52M Convection Oven User Manual


 
25
Installation instructions
Connection to power mains
FRANKE ovens are equipped with a three pole power cable with free terminals.
If the oven is permanently connected to the power supply, install a device to ensure that it
is disconnected from the power supply, with a contacts opening distance (of at least 3
mm) to ensure total disconnection in conditions of category III overvoltage. Make sure:
a) the plug and socket are suitable for a 16A current
b) both are easily accessible and positioned so that no live part can be accessed when
inserting or removing the plug
c) the plug can be easily inserted
d) when plugged in, the oven doesn't rest against the plug when installed in the cabinet
e) the same socket must not be used for two plugs
f) a 3 x 1.5 mm2 cable
type
H05VV-F should be used to replace
the power cable
g) the polarity of connection of the free terminals must be
respected
(Brown=Phase – Blue=Neutral – YellowGreen=Earth)
N.B: make sure that the characteristics of your power system
(voltage, maximum power and current), are compatible with
those of your FRANKE oven.
Place the appliance in the compartment; secure the oven to the unit with
the 4 screws provided, through the holes in its side panels.
If the oven is to be fitted underneath a cooktop, first turn the cooktop
assembly (R) to the right or left so that the oven fits properly.
BLU
MARRONE
BROWN
BLUE
GIALLO-VERDE
YELLOW-GREEN
L
N