Frymaster Protector Series Fryer User Manual


 
2-6
* For distances of more than 20 feet (6 m) and/or more
than 4 fittings or elbows, increase the connection by one
pipe size.
The Protector
®
Series gas fryer has received the CE mark for the countries and gas categories
indicated in the table below. NOTE: The nominal heat input (QN) is 21kW except for AT, DE, LU
and category 3P/B, which is 23kW.
COUNTRIES CATEGORIES GAS PRESSURE (MBAR)
G20 20
AUSTRIA (AT) II2H3B/P
G30, G31 50
I2E(R)B G20, G25 20, 25
BELGIUM (BE)
I3+ G30, G31 28-30, 37
G20 20
DENMARK (DK) II2H3B/P
G30, G31 30
G20, G25 20, 25
II2Esi3+
G30, G31 28-30, 37
G20, G25 20, 25
FRANCE (FR)
II2Esi3P
G31 50
G20 20
FINLAND (FI) II2H3B/P
G30, G31 30
G20, G25 20
II2ELL3B/P
G30, G31 50
GERMANY (DE)
I3P G31 50
G20 20
GREECE (GR) II2H3+
G30, G31 28-30, 37
G20 20
ITALY (IT) II2H3+
G30, G31 28-30, 37
G20 20
IRELAND (IE) II2H3+
G30, G31 28-30, 37
G20 20
LUXEMBOURG (LU) II2E3B/P
G30, G31 50
G25 25
II2L3P
G31 50
G25 25
NETHERLANDS (NL)
II2L3B/P
G30, G31 30
NORWAY (NO) I3B/P G30, G31 30
G20 20
PORTUGAL (PT) II2H3+
G30, G31 28-30, 37
G20 20
II2H3+
G30, G31 28-30, 37
G20 20
SPAIN (ES)
II2H3P
G31 37, 50
G20 20
SWEDEN (SE) II2H3B/P
G30, G31 30
G20 20
UNITED KINGDOM (UK) II2H3+
G30, G31 28-30, 37
CE Standard
Required airflow for the combustion air supply is 2m
3
/h per kW.
1. Connect the quick-disconnect hose to the fryer quick-disconnect under the fryer and to the
building gas line.
NOTE: Some fryers are configured for a rigid connection to the gas supply line. These units
are connected to the gas supply line at the rear of the unit.
CE Approved Gas Categories by Country