Fujitsu MAN3184 Water Dispenser User Manual


 
C141-E124-01EN 3 - 101
Note: Precautions for use of command
If this command is terminated with a CHECK CONDITION status, the sense code/sub-sense code
in the sense data is other than “No defect spare location available [=32-00], and a valid logical
block address (other than X ‘FFFFFFFF’) is displayed in the “Command inherent information”
field, it is necessary for the INIT to reissue this command by the following procedure after
executing recovery processing (shown in Section 5.2) in accordance with the contents of the sense
data.
1. Delete the defect descriptors which precede the defect descriptor that specifies the logical
block address displayed in the “Command inherent information” field of the sense data from
the defect descriptor list specified in this command, and leave that defect descriptor in the list.
Logical block address that indicates the “Command inherent
information” field of the sense data.
XXXX
Defect Descriptor List
Delete
2. Change the “Defect List Length” in the header and add the new ”Defect descriptor list”
corrected in 1), then reissue the REASSIGN BLOCKS command.