Fujitsu MAN3184 Water Dispenser User Manual


 
C141-E124-01EN 4 - 21
4.1.5 Verify error recovery parameters (page code = 7)
The page descriptor format of this MODE SELECT parameter is shown in Figure 4.5.
Bit
Byte
76543210
0 00000111
1 X‘0A’ (Page Length)
2 (Reserved) EER PER DTE DCR
Default00001000
Variable00001111
3 Number of retries during VERIFY.
Default X‘3F’
Variable X‘FF’
4 Correctable Bit Length
Default X‘E9’ (=233 bits)
Variable X‘00’
5-9 X‘0000000000’ (Reserved)
10-11 Recovery Time Limit
Default X‘7530’
Variable X‘FFFF’
Figure 4.5 MODE SELECT parameters: verify error recovery parameters
The error recovery parameters divided in this page descriptor are applicable for the following
commands.
x VERIFY
x WRITE AND VERIFY (verify operation)
Note:
If selecting the SCSI-1/CCS mode in the CHANGE DEFINITION command specification, use
Page code = 1 (Read/Write Error Recovery Parameters) instead of this parameter.
(See the