C141-E124-01EN3 - 20
g) AGD (AIP generation disabled)
This specifies whether or not it is permitted to generate AIP (Asynchronous Information
Protection).
"1" (Prohibited): Prohibited generation
"0"*(Permitted): Permitted generation
* Set at shipping time
h) RTD (reselection timeout delay)
This specifies the reselection timeout delay time.
Bit 1 Bit 0 Reselection Time-out Delay
0 0 250 [ms]*
0 1 3 [ms]
10Reserved
11Reserved
* Set at shipping time
i) Spindle motor start delay time
This specifies the time after power on until the motor starts.
The IDD's motor starts after [(value specified in this parameter) x (IDD's SCSI ID x 0.1)] seconds
from the power is switched on. If X '00' is specified in this parameter, the motor starts immediately
after the power is switched on, no matter what SCSI ID is set in the IDD. Also, the IDD starts the
motor immediately no matter what value is specified in this parameter.
This parameter is enabled only when set in the "Auto Motor Start Mode" with a setting
terminal.