Fujitsu MAN3184, MAN3367, MAN3735 SERIES DISK DRIVES Water Dispenser User Manual


 
C141-E124-01EN3 - 54
Page Code Description Changable Parameter
01 Buffer Overrun / Underrun Page Disable
02 Write Error Counter Page Enable
03 Read Error Counter Page Enable
05 Verify Error Counter Page Enable
06 Non-medium Error Page Enable
0D Tempature Page Disable
0E Start-stop Cycle Counter Page Enable only 0002
0F Application Client Log Page Enable
10 Self-Test Result Log Page Disable
(2) Page length
This field specifies the length in bytes of the following log parameters. If the application client
sends a page length that results in the truncation of any parameter, the device server terminates the
command with CHECK CONDITION status (ILLEGAL REQUEST [=5] / Invalid field in
paramter list [=26-00]).
The log pages contain one or more special data structures called log parameters as shown below. Each log
paramter begins with a 4-byte parameter header followed by one or more bytes of "Parameter Value" data.
Bit
Byte
76543210
0 Parameter Code (MSB)
1 Parameter Code (LSB)
2 DU DS TSD ETC TMC LBIN LP
3 Parameter Length
4
n
Parameter Value
(1) Paramter code
This field identifies the log paramter being transferred for that log page.
~ ~
~