Fujitsu MAN3184, MAN3367, MAN3735 SERIES DISK DRIVES Water Dispenser User Manual


 
C141-E124-01EN 4 - 29
4.1.7 Control mode parameters (page code = 0A)
The page descriptor format of this MODE SELECT parameter is shown in Figure 4.7.
Bit
Byte
76543210
0 00001010
1 X‘0A’ or X‘06’ (Page Length)
2 TST (Reserved) GLTSD RLEC
Default00000000
Variable00000011
3 Queue Algorithm Qualifier Reserved Qerr DQue
Default 0 0 0 0 0 0 0 0
Variable 1 1 1 1 0 0 1 1
4 Reserved RAC Reserved SWP RAERP
UAAERP
EAERP
Default 0 0 0 0 0 0 0 0
Variable 0 0 0 0 0 0 0 0
5 X‘00’ (Reserved)
6-7 Ready Aer Holdoff Period
Default X‘0000’
Variable X‘0000’
8-9 Busy Timeout Period
Default X‘0000’
Variable X‘0000’
10-11 Extended Self-Test Completion Time
Default X‘xxxx’
Variable X‘0000’
Figure 4.7 MODE SELECT parameters: control mode parameters
The parameters defined on this page control the operations of the tagged queuing function and
statistical information function.