a. Page code list
This parameter page specifies transfer of the “Page code” list of the parameter page supported
by the IDD in the SEND DIAGNOSTIC command and the RECEIVE DIAGNOSTIC
RESULTS command to the INIT. Figure 3.19 shows the format of this parameter page. The
page code list supported by the IDD is transferred to the INIT by the RECEIVE
DIAGNOSTIC RESULTS command which is issued following the SEND DIAGNOSTIC
command that specifies this parameter page (shown in Section 3.4.2 (1) )
Bit
Byte
76543210
0 X ‘00’ (Page Code)
100000000
2 X ‘00’ (Page parameter length)
3 X ‘00’ (Page parameter length)
Figure 3.19 SEND DIAGNOSTIC parameters: page code list
b. Logical/physical address conversion
This parameter page specifies conversion of the address information expressed in either the
“Logical Block Address,” “Physical Sector Address” or “Byte Distance from the Index” format
to another expression format. Figure 3.20 shows this parameter page format. The INIT can
specify the address information that should be converted in this parameter page of the SEND
DIAGNOSTIC command, and can read the conversion results by the RECEIVE
DIAGNOSTIC RESULTS command (see Section 3.4.2 (2)).
Bit
Byte
76543210
0 X ‘40’ (Page Code)
100000000
2 X ‘00’ (Page Parameter Length)
3 X ‘0A’ (Page Parameter Length)
400000
Address Format Before Conversion
5 0 0 0 0 0 Address Format After Conversion
6
7
Logical or Physical Address