GE JGBP34GEP Range User Manual


 
~STALLATION
mSTRUCTIONS
(continued)
HOW TO CONVERT THE RANGE FOR USE
WITH
1P
GAS OR NATURAL GAS (continued)
CONVERT TOP BURNER VALVES
1. Turn all top
burners to LOW.
2. Remove all
four knobs.
3. With a small flat
\
\
\
w+=
r
blade screwdriver, turn
the valve set screws
clockwise to decrease
%
flame size, counterclockwise
\
;
//
to increase flame size. Adjust
until the flame is about the same
[
height as the top of the burner.
4. Replace knobs.
5. Check for flame outage by opening and
closing the oven door several times. If the flame
goes out, increase the flame size.
CHECK QUALITY OF
FLWES
The combustion quality of burner flames needs
to be determined visually.
If burner flames look like (A), call for service.
Normal burner flames should look like (B) or
(C), depending on the type of gas you use.
With
LP
gas, some yellow tipping on outer cones
is normal.
(A) Yellow
flames—
Call for service
(B) Yellow tips on
outer
cones—
Normal for
LP
gas
(C)
%fi
blue flame-
Normal for natural gas
48