Setup
12 309535L
4. Tighten all fittings on unit.
5. Fill pumps A and B packing nuts with throat seal liq-
uid (TSL) and torque to 25-30 ft-lb (34-41 N•m). Fol-
low instructions in pump manual.
3. Connect the fluid hose (W) to the fluid manifold out-
let (J). Do not install gun spray tip yet.
6. Fill metering valves A and B packing nuts (H) with
throat seal liquid (TSL) and tighten 1/4 turn after nut
contacts packings; about 145-155 in/lbs (16-18
N•m). Check packing nut tightness after first hour of
operation, again after 24 hours, then check as
needed (when TSL discolors or seeps over packing
nut). Also check tightness whenever unit is trans-
ported.
J
H
7. Connect air supply line to 3/4 npt(f) air filter inlet (F).
8. Turn off air regulator. Open main air shutoff valve.
When starting up, display will show “88888”, then
software revision, then current ratio.
F
TI2218A
Air supply requirement: 110 psi (0.8 MPa, 8 bar)
maximum, 50 psi (0.35 MPa, 3.5 bar) minimum
Flow volume required: 60 scfm minimum; 250
scfm maximum
Model 248842 is designed to use Air Supply Kit
248827.