Graco 309535L Mixer User Manual


 
Priming
18 309535L
Priming
WARNING
Wear gloves if fluid temperature exceeds 110° F (43°
C).
Do not install the gun spray tip yet. Use the lowest
possible pressure to prime to avoid splashing.
1. Fill A and B reservoirs (R) with proper materials.
2. Turn both 3-way ball valves to open reservoir lines
as shown below. Arrow on handle shows direction of
flow.
R
ti2318a
A
B
ti2320a
3. Turn off air regulator. Close fluid shutoff valves A and
B.
4. Place a container under each sampling valve. Open
sampling valve A slowly.
When run independently (set to or ), the
pump runs for 12 cycles, then stops.
Press Start and Stop as needed to prime.
Monitor containers to avoid overflowing.
5. Turn knob to pump A . Press Start . Turn up
air regulator slowly until pump A starts.
I
O
PSI
Bar
MPa
PSI
Bar
MPa
Close
Close
AB
AB
Open
AB
A B
A
I
O
PSI
Bar
MPa
PSI
Bar
MPa
BA
B
A
0
A